A change-of-use approval costs ”generally entails” the sum of three separate things: The Council Lodgement Fee set by regulations, a consultant’s fee for preparing and running the application, and the architectural fees and specialist reports your particular use triggers.

Most operators find out about the third layer after they have already signed the lease. That is where budgets often break. Before you commit to a tenancy or ask anyone for a quote, it is worth understanding which of these three costs are fixed, which is negotiable, and which one depends entirely on what you intend to do inside the building.

What are the three cost layers in a change-of-use approval?

The three layers are the Council fees, the consultant fees, and the architectural fees and specialist reports.

The Council fee is statutory. In New South Wales, it is calculated under Part 13 of the Environmental Planning and Assessment Regulation 2021, and you cannot negotiate it. The consultant fee is what a Town Planner charges to prepare the Statement of Environmental Effects and other planning reports, assemble the application, manage the lodgement and respond to Council. The architectural plans and specialist reports are the variable layer, and they are driven by your intended use, not your building.

A yoga studio and a boxing gym in the identical tenancy will not cost the same to approve. The building is the same. The scale, noise, hours, number of people and the parking demand are not.

How much is the Council lodgement fees for a change of use?

The Council fee is calculated from the estimated development cost of the works, not from the value of the business.

This matters more than most operators expect. If you are changing the use of a tenancy and doing minimal physical work, the estimated development cost is low, and the Council fee follows it down. If the change of use comes bundled with a full fit-out, the fit-out cost drives the fee up.

Three mechanics are worth knowing:

  • Fees are indexed annually. Schedule 4 of the EP&A Regulation sets fees in “fee units”, which are recalculated each financial year. Council fee schedules therefore change around 1 July, and a quote from May may not hold in July.
  • GST is added before the fee is calculated. Since 4 March 2024, GST must be added to the estimated development cost before certain Schedule 4 fees are worked out. The NSW Department’s estimated development cost guidance sets out how this is applied.
  • There is an extra fee above $50,000. Where estimated development cost including GST exceeds $50,000, an additional planning reform service fee is payable to the Planning Secretary on top of the Council fee.

Above $3 million in estimated development cost, the figure must be prepared by a qualified quantity surveyor who is a member of a relevant professional body. Most change-of-use applications sit well below that, however, a large multi-site fit-out programme can cross it.

Most NSW Councils publish a fee estimator on their website. Running your estimated works cost through it before you lease will give you the statutory layer within a few hundred dollars.

What does the consultant fee actually cover?

The consultant fee covers the work of getting the application into a condition that Council can approve.

Market rates for town planning work in Australia sits in a wide band. Hourly rates run from roughly $120 to over $500, and full development application preparation is commonly quoted between $3,000 and $10,000 depending on complexity. Change-of-use applications typically sit in the lower to middle part of that band, because they usually involve less built form than a new building.

Prestige quotes minimum fee packages based on hourly fee rate schedules and expected minimum work scopes, so the consultant layer is confidently known before any works start.

The work behind that fee is not primarily administrative. It is a permissibility check against the zone and the local environmental plan, a Statement of Environmental Effects, a development control plan compliance assessment covering parking and amenity, coordination of the specialist consultants, lodgement through the NSW Planning Portal, and management of any request for information Council issues afterwards.

That last item is where the fee earns itself. A request for information stops the assessment clock, and it stays stopped until you answer it.

Which specialist reports does your use type actually trigger?

The reports you need are determined by the impacts your use creates, and they are largely predictable once you know the use.

This is the layer competitors either omit or bury under “it depends”. It does depend, however, on a short and knowable list:

  • Acoustic report: triggered by gyms, studios, bars, live music venues and any use with plant running outside standard hours. Free weights dropped on a slab transmit through the structure, not just the air.
  • Traffic and parking assessment: triggered where the new use generates more parking demand than the old one. Development control plans set parking rates per square metre, and gyms and food premises generally sit at higher rates than warehousing or office uses for example.
  • Fire safety and egress advice: triggered where the building classification changes, particularly into Class 9b assembly use.
  • Mechanical ventilation and waste: triggered by food premises, commercial kitchens and any use with grease, fumes or significant waste volume.
  • Accessibility assessment: triggered where a change in building classification or new construction works are proposed. 
  • Contamination assessment: triggered where a site with an industrial history is converted to a use involving sensitive occupants, such as childcare or health.

Each report carries its own fee, paid to that consultant rather than to your planner.

Why do gyms and food premises sit at the top of the cost range?

Gyms and food premises cost more because they trigger the most reports and the most sensitive assessment.

A gym in an industrial or commercial tenancy usually needs to be characterised as a recreation facility (indoor) under the Standard Instrument land use definitions, which cover gymnasiums and health studios. That characterisation almost always brings an acoustic assessment and a parking assessment with it. It also frequently brings a building classification change into Class 9b, which the National Construction Code defines as an assembly building where people gather for recreational or sporting purposes.

Food premises follow a similar pattern for different reasons: mechanical ventilation, waste storage, grease arrestors, hours of operation and, where alcohol is involved, an additional licensing pathway that runs alongside the planning approval rather than inside it.

Prestige’s work in this area is concentrated rather than incidental. Studio P Architecture & Interiors, an architecture practice the firm has worked alongside for years, describes the relationship in its testimonial: “over the past decade, we’ve partnered with Martin on more than fifty projects”, and specifically credits a deep understanding of Class 9b gymnasium planning requirements. The firm has also acted for numerous Anytime Fitness franchisees as preferred supplier and for the Jym Group.

What does the approval cost by business type?

The table below sets out the pattern by use, not the price. Report requirements are drawn from standard NSW development control plans and National Construction Code triggers.

Use typeBuilding classification changeReports commonly triggeredRelative approval cost
Warehouse to gym or studioClass 7b to Class 9bAcoustic, parking, fire, structural and egressHigh
Retail shop to café or restaurantClass 6 (may remain)Mechanical ventilation, waste, acoustic if extended hoursHigh
Office to medical centreClass 5 to Class 9a or Class 5Parking, accessibility, wasteMedium to high
Warehouse to indoor recreation, low intensityClass 7b to Class 9bAcoustic, parking, fire, structural and egressMedium to high
Shop to office or consulting roomsClass 6 to Class 5Parking, accessibilityLow to medium
Like-for-like retail tenant changeUsually noneOften noneLow

The final column is deliberately relative. Absolute figures move with Council, with the current fee schedule and with the condition of the building you have chosen.

If you are still comparing tenancies, this is the point where an early read is worth more than a quote. Our development application services start with exactly that question: whether the use is permissible in the zone, and what the building will make you pay for.

What costs catch operators out after the lease is signed?

The costs that hurt are the ones created by a building decision made before anyone checked the planning position.

Five recur:

  1. Parking shortfall. The tenancy has fewer spaces than the development control plan requires for the new use. Resolving it means a traffic report arguing the shortfall, a cash contribution, or a reduced operating capacity.
  2. Acoustic separation. A shared wall with a sensitive neighbour turns an acoustic report into an acoustic treatment, and treatment is construction cost, not approval cost.
  3. Existing unauthorised works. The previous tenant altered the tenancy without approval. Regularising that becomes your problem, because it is your application.
  4. Building upgrades. Upgrades to building structures for BCA compliance and structural integrity are some of the highest costing aspects of a project, including fire, access, structural adequacy and energy efficiency.
  5. Assessment delay. Council’s assessment period for a standard development application is 40 days under the EP&A Regulation, however, that clock stops while a request for information is outstanding. Rent runs continuously. Assessment time does not.

None of these are exotic. All of them are cheaper to find before the lease than after it.

How do you keep the cost down without risking a refusal?

You reduce cost by resolving permissibility and report scope before you commit, not by removing reports from the application.

Three decisions do most of the work. Check zone permissibility for your specific land use term before signing anything. Scope the reports early, so that quotes are competitive rather than urgent. And get the estimated development cost right, because an inflated figure inflates the statutory fee and an understated one invites a Council challenge.

Cutting a required report out of an application does not save money. It converts a fee into a request for information, and a request for information into rent paid on a tenancy you cannot trade from.

What should you sort out before you commit to a tenancy?

Resolve permissibility and report scope first, because those two answers determine every number that follows. That conversation is worth having whether you are still comparing tenancies or have already signed one.

Prestige Town Planning works on commercial fit-out, change-of-use and Class 9b approvals Nationally, from an office in East Gosford. The firm’s stated position is that if a site cannot support what you are trying to build, you hear it on the first call, and that it does not bill for work you do not need.

Call (02) 4308 7305, Monday to Friday, 9 am to 5 pm, or use the contact form to send through the tenancy address and what you intend to operate. You will get a read on whether it stacks up. If it does not, that is the answer you get.

We're ready when you are

Whether you’re at the concept stage or chasing certificates, we’ll give you clear answers, smart advice and a plan that works.